<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-13 17-31-18
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 52 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 70 kHz 14027 4,8264
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,6 dBr 5,08 dBr 6,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 70 kHz MIN: 13 kHz % above 76 kHz: 4,8264 Acquired: 2025/07/13 17.30.14 Total samples: 14027 Equivalent time: 0:11:41 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 6,2 dBr MIN: 3,6 dBr AVE: 5,08 dBr % above 12,2 dBr: 0,0 Last value: 5,0 dBr (2025/07/13 17.30.14) 17.16 17.18 17.20 17.22 17.24 17.26 17.28 17.30 0 2 4 6 Pm [dBr]